NII Technical Report (NII-2009-015E):Asynchronous Pipeline Controller Based on Early Acknowledgement Protocol

https://doi.org/10.20736/0002000528
https://doi.org/10.20736/0002000528
2abdf2e9-6aba-471d-8a67-daf57e259a21
名前 / ファイル ライセンス アクション
09-015E.pdf NII Technical Report (NII-2009-015E):Asynchronous Pipeline Controller Based on Early Acknowledgement Protocol (506 KB)
Item type レポート / Report(1)
公開日 2022-07-27
タイトル
タイトル NII Technical Report (NII-2009-015E):Asynchronous Pipeline Controller Based on Early Acknowledgement Protocol
言語 en
言語
言語 eng
キーワード
言語 ja
主題Scheme Other
主題 テクニカルレポート
キーワード
言語 en
主題Scheme Other
主題 Technical Report
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.20736/0002000528
ID登録タイプ JaLC
著者 Mannakkara, Chammika

× Mannakkara, Chammika

en Mannakkara, Chammika

Search repository
米田, 友洋

× 米田, 友洋

ja 米田, 友洋

en Yoneda, Tomohiro

Search repository
抄録
内容記述タイプ Abstract
内容記述 A new pipeline controller based on the Early Acknowledgement (EA) protocol is proposed for bundled-data asynchronous circuits. The EA protocol indicates acknowledgement by the falling edge of the acknowledgement signal in contrast to the 4-phase protocol, which indicates it on the rising edge. Thus, it can hide the overhead caused by the resetting period of the handshake cycle. Since we have designed our controller assuming several timing constraints, we first analyze the timing constraints under which our controller correctly works and then discuss their appropriateness. The performance of the controller is compared both analytically and experimentally with those of two other pipeline controllers, namely, a very high-speed 2-phase controller and an ordinary 4-phase controller. Our controller performs better than 4-phase controller when pipeline has processing elements. We have obtained interesting results in the case of a non-linear pipeline with a Conditional Branch (CB) operation. Our controller has slightly better performance even compared to 2-phase controller in the case of a pipeline with processing elements. Its superiority lies in the EA protocol, which employs return-to-zero control signals like the 4-phase protocol. Hence, our controller for CB operation is simple in construction just like the 4-phase controller. A 2-phase controller for the same operation needs to have a slightly complicated mechanism to handle the 2-phase operation because of the non-return-to-zero control signals, and this results in a performance overhead.
言語 en
書誌情報 ja : NIIテクニカル・レポート
en : NII Technical Report

p. 1-20, 発行日 2009-09-29
出版者
出版者 国立情報学研究所
言語 ja
ISSN
収録物識別子タイプ ISSN
収録物識別子 1346-5597
戻る
0
views
See details
Views

Versions

Ver.1 2022-07-27 06:14:59.910611
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3