{"_buckets": {"deposit": "1ddfe118-98aa-4345-b998-09dfa61ffa4d"}, "_deposit": {"id": "1247", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "1247"}, "status": "published"}, "_oai": {"id": "oai:repository.nii.ac.jp:00001247", "sets": ["136"]}, "author_link": [], "control_number": "1247", "item_5_biblio_info_30": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-09-24", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "18", "bibliographicPageStart": "1", "bibliographic_titles": [{"bibliographic_title": "NIIテクニカル・レポート", "bibliographic_titleLang": "ja"}, {"bibliographic_title": "NII Technical Report", "bibliographic_titleLang": "en"}]}]}, "item_5_description_28": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A new pipeline controller based on Early Acknowledgement protocol is proposed for bundled-data asynchronous circuits. The Early Acknowledgement protocol indicates acknowledgement by the falling edge of the acknowledgement signal in contrast to the 4-phase protocol which indicates it on the rising edge. Thus, it can hide the overhead caused by a resetting phase of the handshake cycle. Since we have designed our controller assuming several timing constraints, we first analyze the timing constraints under which our controller correctly works, and discuss the appropriateness. Advantages of employing the Early Acknowledgement protocol in a pipeline controller is demonstrated by comparing performance of the proposed controller with that of two other pipeline controllers, namely, a very high-speed 2-phase controller and an ordinary 4-phase controller, both analytically and experimentally. We have obtained interesting results in the case of a non-linear pipeline with a Conditional Branch operation. Since Early Acknowledgement protocol employs return-to-zero control signals like 4-phase protocol, our controller for Conditional Branch operation is simple in construction identically to the 4-phase controller. A 2-phase controller for the same operation needs to have a little complicated mechanism to handle the 2-phase operation due to non-return-to-zero control signals. For such simplicity of the implementation, our controller has a slightly better performance compared to the 2-phase controller when each stage has a processing element. Thanks to the superiority of the Early Acknowledgement protocol, our controller substantially outperforms the 4-phase controller too.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_5_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.20736/0000001247", "subitem_identifier_reg_type": "JaLC"}]}, "item_5_publisher_31": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "国立情報学研究所", "subitem_publisher_language": "ja"}]}, "item_5_source_id_32": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1346-5597", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mannakkara, Chammika", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "米田, 友洋", "creatorNameLang": "ja"}, {"creatorName": "Yoneda, Tomohiro", "creatorNameLang": "en"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-03-12"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "08-009E.pdf", "filesize": [{"value": "771.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 771900.0, "url": {"label": "NII Technical Report (NII-2008-009E):Asynchronous Pipeline Controller Based on Early Acknowledgement Protocol", "url": "https://repository.nii.ac.jp/record/1247/files/08-009E.pdf"}, "version_id": "4550b999-9024-4e16-8e17-7d8aa7da996c"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "テクニカルレポート", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Technical Report", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "NII Technical Report (NII-2008-009E):Asynchronous Pipeline Controller Based on Early Acknowledgement Protoco", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "NII Technical Report (NII-2008-009E):Asynchronous Pipeline Controller Based on Early Acknowledgement Protoco", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["136"], "permalink_uri": "https://doi.org/10.20736/0000001247", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2019-03-12"}, "publish_date": "2019-03-12", "publish_status": "0", "recid": "1247", "relation": {}, "relation_version_is_last": true, "title": ["NII Technical Report (NII-2008-009E):Asynchronous Pipeline Controller Based on Early Acknowledgement Protoco"], "weko_shared_id": -1}
  1. NIIテクニカル・レポート

NII Technical Report (NII-2008-009E):Asynchronous Pipeline Controller Based on Early Acknowledgement Protoco

https://doi.org/10.20736/0000001247
https://doi.org/10.20736/0000001247
cf17dbe1-8a46-4abe-a8b6-c82400844fcd
名前 / ファイル ライセンス アクション
08-009E.pdf NII Technical Report (NII-2008-009E):Asynchronous Pipeline Controller Based on Early Acknowledgement Protocol (771.9 kB)
Item type レポート / Report(1)
公開日 2019-03-12
タイトル
言語 en
タイトル NII Technical Report (NII-2008-009E):Asynchronous Pipeline Controller Based on Early Acknowledgement Protoco
言語
言語 eng
キーワード
言語 ja
主題Scheme Other
主題 テクニカルレポート
キーワード
言語 en
主題Scheme Other
主題 Technical Report
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.20736/0000001247
ID登録タイプ JaLC
著者 Mannakkara, Chammika

× Mannakkara, Chammika

en Mannakkara, Chammika

Search repository
米田, 友洋

× 米田, 友洋

ja 米田, 友洋

en Yoneda, Tomohiro

Search repository
抄録
内容記述タイプ Abstract
内容記述 A new pipeline controller based on Early Acknowledgement protocol is proposed for bundled-data asynchronous circuits. The Early Acknowledgement protocol indicates acknowledgement by the falling edge of the acknowledgement signal in contrast to the 4-phase protocol which indicates it on the rising edge. Thus, it can hide the overhead caused by a resetting phase of the handshake cycle. Since we have designed our controller assuming several timing constraints, we first analyze the timing constraints under which our controller correctly works, and discuss the appropriateness. Advantages of employing the Early Acknowledgement protocol in a pipeline controller is demonstrated by comparing performance of the proposed controller with that of two other pipeline controllers, namely, a very high-speed 2-phase controller and an ordinary 4-phase controller, both analytically and experimentally. We have obtained interesting results in the case of a non-linear pipeline with a Conditional Branch operation. Since Early Acknowledgement protocol employs return-to-zero control signals like 4-phase protocol, our controller for Conditional Branch operation is simple in construction identically to the 4-phase controller. A 2-phase controller for the same operation needs to have a little complicated mechanism to handle the 2-phase operation due to non-return-to-zero control signals. For such simplicity of the implementation, our controller has a slightly better performance compared to the 2-phase controller when each stage has a processing element. Thanks to the superiority of the Early Acknowledgement protocol, our controller substantially outperforms the 4-phase controller too.
言語 en
書誌情報 ja : NIIテクニカル・レポート
en : NII Technical Report

p. 1-18, 発行日 2008-09-24
出版者
言語 ja
出版者 国立情報学研究所
ISSN
収録物識別子タイプ ISSN
収録物識別子 1346-5597
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 06:04:52.644314
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3